PublicadoEl 23/11/22 por Comillas
Capítulo de libro

Impact of PLL control on small-signal stability of wind DFIGs

tipo de documento semantico ckh_publication

Ficheros

IIT-20-070A.pdf
Tamaño 1105902
Formato Adobe PDF
Fecha de publicación 03/08/2020
Fuente Libro: IEEE Power & Energy Society General Meeting - IEEE PES GM 2020, Página inicial: 1-5, Página final:
Estado info:eu-repo/semantics/publishedVersion

Resumen

Idioma es-ES
Idioma en-GB
Resumen

This paper investigates the small-signal stability of wind doubly fed induction generators. Precisely, the impact of the phase locked loop control on the small-signal stability of wind doubly fed induction generators is addressed. Modal analysis technique is used. Making use of a very detailed model of the wind generator, stability conditions in terms of the ratio between the bandwidth of generator current controllers and the bandwidth of phase locked loop controller have been obtained. In addition, the sensitivity with respect to the grid impedance is studied.

Editorial Institute of Electrical and Electronics Engineers Power and Energy Society (Montréal, Canadá)
Grupos de investigación y líneas temáticas Instituto de Investigación Tecnológica (IIT)

Palabras clave

Tipo de archivo application/pdf
Idioma en-GB
Tipo de acceso info:eu-repo/semantics/restrictedAccess
Fecha de modificacion 09/09/2022
Fecha de disponibilidad 28/06/2021
fecha de alta 28/06/2021

Categorías:

Compartida con: