PublicadoEl 23/11/22 por Comillas
Artículo

CFD analysis on the effect of combining positive and negative pressure during the irrigation of artificial isthmuses

tipo de documento semantico ckh_publication

Ficheros

IIT-20-086A.pdf
Tamaño 1121192
Formato Adobe PDF
Fecha de publicación 02/10/2020
Fuente Revista: International Journal for Numerical Methods in Biomedical Engineering, Periodo: 1, Volumen: online, Número: 10, Página inicial: e3385-1, Página final: e3385-10
Estado info:eu-repo/semantics/publishedVersion

Resumen

Idioma es-ES
Idioma en-GB
Resumen

Fluid dynamics generated by irrigation needles have not been deeply analyzed in root canal irregularities such as apical ramifications or isthmus where the cleaning capacity of irrigants might be compromised and hence the treatment outcome. The goal of this study was to compare the key irrigation parameters (flow pattern, irrigant velocity, apical pressure, and shear stress) between two irrigation needles and the additional effect of aspiration cannulas through computational fluid dynamics. A 3D-model consisting of two canals linked by an isthmus was modeled. The abovementioned needles irrigated the primary canal, whereas an aspiration cannula was located inside the secondary canal. Both the geometry definition and spatial discretization were carried out with ANSYS 16.2, through which six different simulations were performed: lateral exit (LE) needle, frontal exit (FE) needle, LE and cannula in crown (LEC), FE and cannula in crown (FEC), LE and cannula in middle third (LEM), FE and cannula in middle third (FEM). FE and FEM showed that the irrigation flow only passes through the isthmus in the most apical section (maximum irrigant velocity / shear stress = 8.44 m/s / 1628.44 Pa and 8.63 m/s / 1185.69 Pa, respectively). However, the remaining simulations showed the irrigation flow passing through the isthmus twice, through the most apical section first and through the upper part of the isthmus later (maximum irrigant velocity / shear stress = 8.48 m/s / 1298.24 Pa (LE), 8.61 m/s / 1261.36 Pa (LEM), 8.61 m/s / 1355.24 Pa (LEC), 8.59 m/s / 1256.87 Pa (FEC)). Furthermore, the highest velocity values were detected when aspiration cannulas were added.

Grupos de investigación y líneas temáticas Instituto de Investigación Tecnológica (IIT)

Palabras clave

Tipo de archivo application/pdf
Idioma en-GB
Tipo de acceso info:eu-repo/semantics/restrictedAccess
Fecha de modificacion 09/09/2022
Fecha de disponibilidad 07/06/2021
fecha de alta 07/06/2021

Categorías:

Compartida con: